Anonymous | Login | 2024-05-19 16:47 CEST |
Main | My View | View Issues |
Viewing Issue Simple Details [ Jump to Notes ] | [ View Advanced ] [ Issue History ] [ Print ] | ||||||
ID | Category | Severity | Reproducibility | Date Submitted | Last Update | ||
0004387 | [smartmontools] packaging | major | always | 2010-04-01 20:33 | 2012-02-26 12:34 | ||
Reporter | bonivart | View Status | public | ||||
Assigned To | |||||||
Priority | normal | Resolution | fixed | ||||
Status | closed | ||||||
Summary | 0004387: Class actions are never triggered so no init script is installed | ||||||
Description |
I just supported a used over IRC and he didn't get any init script when install smartmontools. He had cswclassutils installed and no sparse zone or anything. I noticed that you have this is the prototype: f cswinitsmf /etc/opt/csw/init.d/cswsmartd 0755 root bin But in pkginfo only class none is listed: CLASSES=none So the class action is never triggered and even worse, the init script is not installed at all. |
||||||
Additional Information | I think an update of the GAR recipe would solve this since this is an old package from 2008 with static prototypes and so on. | ||||||
Tags | No tags attached. | ||||||
Attached Files | |||||||
|
Notes | |
(0007811) bonivart (developer) 2010-04-01 20:37 |
Maybe use the new source 5.39.1 while you're at it..? ;-) |
(0009660) maciej (reporter) 2012-02-26 12:34 |
5.42,REV=2011.12.15 is now released and uses SMF support http://buildfarm.opencsw.org/pkgdb/srv4/8f536b33a65e6380a82522258eaa50c0/ [^] |