OpenCSW Bug Tracker


Viewing Issue Simple Details Jump to Notes ] View Advanced ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0004387 [smartmontools] packaging major always 2010-04-01 20:33 2012-02-26 12:34
Reporter bonivart View Status public  
Assigned To
Priority normal Resolution fixed  
Status closed  
Summary 0004387: Class actions are never triggered so no init script is installed
Description I just supported a used over IRC and he didn't get any init script when install smartmontools. He had cswclassutils installed and no sparse zone or anything. I noticed that you have this is the prototype:

f cswinitsmf /etc/opt/csw/init.d/cswsmartd 0755 root bin

But in pkginfo only class none is listed:

CLASSES=none

So the class action is never triggered and even worse, the init script is not installed at all.
Additional Information I think an update of the GAR recipe would solve this since this is an old package from 2008 with static prototypes and so on.
Tags No tags attached.
Attached Files

- Relationships

-  Notes
(0007811)
bonivart (developer)
2010-04-01 20:37

Maybe use the new source 5.39.1 while you're at it..? ;-)
(0009660)
maciej (reporter)
2012-02-26 12:34

5.42,REV=2011.12.15 is now released and uses SMF support

http://buildfarm.opencsw.org/pkgdb/srv4/8f536b33a65e6380a82522258eaa50c0/ [^]