OpenCSW Bug Tracker


Viewing Issue Simple Details Jump to Notes ] View Advanced ] Issue History ] Print ]
ID Category Severity Reproducibility Date Submitted Last Update
0003637 [cswclassutils] regular use feature have not tried 2009-04-13 21:19 2010-06-09 19:27
Reporter dam View Status public  
Assigned To bonivart
Priority normal Resolution fixed  
Status closed  
Summary 0003637: UID range for daemons
Description It would be nice to have a global config file to specify the UID range for daemons,
line
DAEMON_UID_LOW = 1100
DAEMON_UID_HIGH = 1199
Additional Information
Tags No tags attached.
Attached Files

- Relationships

-  Notes
(0005993)
bonivart (developer)
2009-04-21 17:31

I will use something like usergroup_uid_low and usergroup_uid_high to resemble the already existing usergroup_remove setting. I think it's a good idea to be clear about which script the settings belong to.

I will look into this soon but I have a few bugs to take care of first.
(0007448)
bonivart (developer)
2010-02-16 11:15

Sebastian is working on this.
(0007784)
bonivart (developer)
2010-03-31 22:02

This was merged into cswclassutils with r8957.
(0008002)
bonivart (developer)
2010-06-09 19:27

cswclassutils 1.37 released to current.

- Issue History
Date Modified Username Field Change
2009-04-13 21:19 dam New Issue
2009-04-21 17:25 bonivart Status new => assigned
2009-04-21 17:25 bonivart Assigned To => bonivart
2009-04-21 17:31 bonivart Note Added: 0005993
2010-02-16 11:15 bonivart Note Added: 0007448
2010-03-31 22:02 bonivart Note Added: 0007784
2010-03-31 22:02 bonivart Status assigned => resolved
2010-03-31 22:02 bonivart Resolution open => fixed
2010-06-09 19:27 bonivart Note Added: 0008002
2010-06-09 19:27 bonivart Status resolved => closed


Copyright © 2000 - 2008 Mantis Group